{"id":953,"date":"2024-10-30T15:15:23","date_gmt":"2024-10-30T13:15:23","guid":{"rendered":"https:\/\/wastetech.gr\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/"},"modified":"2025-06-09T19:39:04","modified_gmt":"2025-06-09T19:39:04","slug":"ypovrychia-antlia-apostrangisis-solinotou-typou-jc","status":"publish","type":"page","link":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/","title":{"rendered":"Submersible drainage center-line pumps JC &amp; XJC"},"content":{"rendered":"\n\n\t<section class=\"section product-top\" id=\"section_777170687\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1090922865\">\n\n\n\t<div id=\"col-1546279243\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-1931702872\" class=\"text\">\n\t\t\n\n<h1 class=\"jumbo-heading mb-0\">Submersible drainage center-line pumps JC &amp; XJC<\/h1>\n\t\t\n<style>\n#text-1931702872 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\t<div id=\"gap-620032772\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-620032772 {\n  padding-top: 50px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<div class=\"row align-middle white\"  id=\"row-1454348995\">\n\n\n\t<div id=\"col-1748272971\" class=\"col medium-5 small-12 large-5\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_30919092\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 100px;\">\n\t\t\t<img decoding=\"async\" width=\"2560\" height=\"2097\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-scaled.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-scaled.jpg 2560w, https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-300x246.jpg 300w, https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-1024x839.jpg 1024w, https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-768x629.jpg 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-1536x1258.jpg 1536w, https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/05\/Endiameso_JC-and-XJC-2048x1678.jpg 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_30919092 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1748272971 > .col-inner {\n  padding: 50px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1488033286\" class=\"col medium-7 small-12 large-7\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h2 class=\"smaller-heading mb-0 waste-blue-text\">Perfect for small space installations<\/h2>\n\t<div id=\"gap-820950111\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-820950111 {\n  padding-top: 40px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<p>Submersible drainage center-line pumps JC and XJC are excellent for pumping water and dirty water mixed with light abrasives. The slim design makes them easy to move and easy to handle, and they are perfect for applications with limited installation space.<\/p>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1488033286 > .col-inner {\n  padding: 10px 10px 0px 10px;\n}\n@media (min-width:550px) {\n  #col-1488033286 > .col-inner {\n    padding: 50px 40px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\n<style>\n#row-1454348995 > .col > .col-inner {\n  background-color: rgb(255, 255, 255);\n}\n<\/style>\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_777170687 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n  background-color: rgb(237, 239, 242);\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section service-info\" id=\"section_843452668\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\" style=\"max-width:1180px\" id=\"row-90305064\">\n\n\n\t<div id=\"col-937763761\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-3656557956\" class=\"text\">\n\t\t\n\n<h3 class=\"smaller-title waste-blue-text mb-0\">MAIN BENEFITS<\/h3>\n\t\t\n<style>\n#text-3656557956 {\n  text-align: center;\n}\n@media (min-width:550px) {\n  #text-3656557956 {\n    text-align: left;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-1146325729\" class=\"gap-element clearfix show-for-small\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1146325729 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\n\t<div id=\"gap-1037365108\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1037365108 {\n  padding-top: 40px;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-2264155359\" class=\"text what-win-box\">\n\t\t\n\n<p>Plug- and-pump installation without having to worry about overheating<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-3216414387\" class=\"text what-win-box\">\n\t\t\n\n<p>Reliable, trouble-free operation also at low water levels<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-2445578045\" class=\"text what-win-box\">\n\t\t\n\n<p>Pumps with built-in AquaTronic unit will adjust incorrect phase order, ensuring correct impeller rotation (XJC)<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-885894217\" class=\"text what-win-box\">\n\t\t\n\n<p>Modular design increases serviceability and makes it easy to convert the pump for different hydraulic requirements<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-1528082734\" class=\"text what-win-box\">\n\t\t\n\n<p>Pumps with built-in AquaTronic can be checked without disassembly, using its service software (XJC)<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1546882592\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-1665038114\" class=\"text\">\n\t\t\n\n<h3 class=\"smaller-title waste-blue-text mb-0\">MAIN APPLICATIONS<\/h3>\n\t\t\n<style>\n#text-1665038114 {\n  text-align: center;\n}\n@media (min-width:550px) {\n  #text-1665038114 {\n    text-align: left;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-1936038763\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1936038763 {\n  padding-top: 40px;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-769750299\" class=\"text what-win-box\">\n\t\t\n\n<p>Drainage applications with limited installation space<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-1263485274\" class=\"text what-win-box\">\n\t\t\n\n<p>Drainage &amp; Flood control projects<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-866444502\" class=\"text what-win-box\">\n\t\t\n\n<p>Construction site dewatering<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 24px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-316-3.svg\" class=\"attachment-medium size-medium\" alt=\"\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n\t<div id=\"text-1467744072\" class=\"text what-win-box\">\n\t\t\n\n<p>Pumping of water and dirty water mixed with light abrasives<\/p>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t<\/div>\n\t\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_843452668 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section product-vertical-tabs-section\" id=\"section_1664060141\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-180606517\">\n\n\n\t<div id=\"col-224223272\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\n\t\t<div class=\"tabbed-content\">\n\t\t\t\n\t\t\t<ul class=\"nav nav-line nav-vertical nav-uppercase nav-size-normal nav-left\" role=\"tablist\"><li id=\"tab-main-design-features\" class=\"tab active has-icon\" role=\"presentation\"><a href=\"#tab_main-design-features\" role=\"tab\" aria-selected=\"true\" aria-controls=\"tab_main-design-features\"><span>MAIN DESIGN FEATURES<\/span><\/a><\/li>\n<li id=\"tab-key-charecteristics\" class=\"tab has-icon\" role=\"presentation\"><a href=\"#tab_key-charecteristics\" tabindex=\"-1\" role=\"tab\" aria-selected=\"false\" aria-controls=\"tab_key-charecteristics\"><span>KEY CHARECTERISTICS<\/span><\/a><\/li>\n<li id=\"tab-documents\" class=\"tab has-icon\" role=\"presentation\"><a href=\"#tab_documents\" tabindex=\"-1\" role=\"tab\" aria-selected=\"false\" aria-controls=\"tab_documents\"><span>DOCUMENTS<\/span><\/a><\/li><\/ul><div class=\"tab-panels\"><div id=\"tab_main-design-features\" class=\"panel active entry-content\" role=\"tabpanel\" aria-labelledby=\"tab-main-design-features\">\n\n<ol>\n<li>In XJC pump models, an optional AquaTronic unit can be used instead of a built-in contactor. The AquaTronic unit compensates for incorrect phase order, which ensures correct motor rotation every time. In JC pump models, a built-in contactor with an automatic restart function protects the motor.<\/li>\n<li>An impeller and wear ring in white cast iron, as well as diffusers coated in oil-resistant nitrile rubber, provide high abrasion resistance.<\/li>\n<li>Double mechanical shaft seals in an oil bath, with primary seal surfaces in silicon carbide and secondary seal surfaces in silicon carbide on carbon, extend the life of the pump. Pumps XJC 50 &#8211; XJC 110 have a double cable-entry seal system that increases the protection against moisture entering the electrical junction area. A double outer casing and good heat convection enable the pump to operate continuously at low levels \u2013 or even run dry without damaging the motor.<\/li>\n<li>Due to the modular design, the same parts can be used for different pumps, which lowers the overall service costs. The adjustable wear ring ensures proper clearance throughout the impeller lifetime. External inspection ports for the oil and motor chambers enable quick and easy evaluation of the shaft seal during service. By removing the top cover of the pump, the electrical junction area can easily be checked.<\/li>\n<li>Pumps XJC 50 &#8211; XJC 110 are equipped with high-efficiency motors and new hydraulics, which combine with low-friction bearings to reduce power losses. The result is low total energy costs and minimized carbon footprint.<\/li>\n<li>Pumps XJC 50 &#8211; XJC 110 allow conversion between high-volume and high-head hydraulics with only a few parts, ensuring the right performance for the application.<\/li>\n<\/ol>\n\n<\/div>\n<div id=\"tab_key-charecteristics\" class=\"panel entry-content\" role=\"tabpanel\" aria-labelledby=\"tab-key-charecteristics\">\n\n<table>\n<tbody>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Submersible drainage pump\u00a0<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>JC 34<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>XJC 50<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>XJC 80<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>XJC 110<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Maximum submergence<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20\u00a0m<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20\u00a0m<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20\u00a0m<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20\u00a0m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Protection class<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>IP 68<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>IP 68<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>IP 68<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>IP 68<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Max. temperature of pumped medium at max. power input and continuous duty<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>40<sup>o<\/sup>C<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>40<sup>o<\/sup>C<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>40<sup>o<\/sup>C<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>40<sup>o<\/sup>C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Max. media density<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>1,100 kg\/m3<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>1,100 kg\/m3<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>1,100 kg\/m3<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>1,100 kg\/m3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>pH of the pumped medium<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>5-8<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>5-8<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>5-8<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>5-8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Strainer hole<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>8\u00a0x\u00a033 mm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>7.5 x 22 mm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>7.5 x 22 mm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>7.5 x 22 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Max number of starts<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>30\/hour<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>30\/hour<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>30\/hour<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>30\/hour<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Motor rating P2<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>3.0 kW<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>5.6 kW<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>8.3 kW<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>11.8\u00a0kW<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Speed<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>2,850 rpm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>2,930 rpm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>2,920 rpm<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>2,920 rpm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"143\"style=\"border-bottom: 1px solid gray;\">\n<p><strong>Power cable<\/strong><\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20 m type H07RN8-F<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20 m type H07RN8-F<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20 m type H07RN8-F<\/p>\n<\/td>\n<td width=\"113\"style=\"border-bottom: 1px solid gray;\">\n<p>20 m type H07RN8-F<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<\/div>\n<div id=\"tab_documents\" class=\"panel entry-content\" role=\"tabpanel\" aria-labelledby=\"tab-documents\">\n\n<p>Brochure &#8211; Submersible Dewatering Pumps<\/p>\n\n\t<a class=\"plain\" href=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/01\/submersible_dewatering_pumps_e10361_en_web.pdf\" target=\"_blank\" rel=\"noopener\" >\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 20px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"244\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png 244w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-833x1024.png 833w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-768x944.png 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1249x1536.png 1249w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1665x2048.png 1665w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg.png 1667w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n<h3>submersible_dewatering_pumps_e10361_en<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\t<\/a>\n\t\n<hr \/>\n<p>Technical Data Sheet &#8211; Submersible drainage center-line pump JC 34<\/p>\n\n\t<a class=\"plain\" href=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/01\/JC_34_TDS_EN.pdf\" target=\"_blank\" rel=\"noopener\" >\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 20px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"244\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png 244w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-833x1024.png 833w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-768x944.png 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1249x1536.png 1249w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1665x2048.png 1665w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg.png 1667w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n<h3>JC_34_TDS_EN<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\t<\/a>\n\t\n<hr \/>\n<p>Technical Data Sheet &#8211; Submersible drainage center-line pump XJC 50<\/p>\n\n\t<a class=\"plain\" href=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/01\/XJC_50_TDS_EN.pdf\" target=\"_blank\" rel=\"noopener\" >\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 20px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"244\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png 244w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-833x1024.png 833w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-768x944.png 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1249x1536.png 1249w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1665x2048.png 1665w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg.png 1667w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n<h3>XJC_50_TDS_EN<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\t<\/a>\n\t\n<hr \/>\n<p>Technical Data Sheet &#8211; Submersible drainage center-line pump XJC 80<\/p>\n\n\t<a class=\"plain\" href=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/01\/XJC_80_TDS_EN.pdf\" target=\"_blank\" rel=\"noopener\" >\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 20px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"244\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png 244w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-833x1024.png 833w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-768x944.png 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1249x1536.png 1249w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1665x2048.png 1665w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg.png 1667w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n<h3>XJC_80_TDS_EN<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\t<\/a>\n\t\n<hr \/>\n<p>Technical Data Sheet &#8211; Submersible drainage center-line pump XJC 110<\/p>\n\n\t<a class=\"plain\" href=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/01\/XJC_110_TDS_EN.pdf\" target=\"_blank\" rel=\"noopener\" >\t<div class=\"icon-box featured-box icon-box-left text-left\"  >\n\t\t\t\t\t<div class=\"icon-box-img\" style=\"width: 20px\">\n\t\t\t\t<div class=\"icon\">\n\t\t\t\t\t<div class=\"icon-inner\" >\n\t\t\t\t\t\t<img decoding=\"async\" width=\"244\" height=\"300\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-244x300.png 244w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-833x1024.png 833w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-768x944.png 768w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1249x1536.png 1249w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg-1665x2048.png 1665w, https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/11\/PDF_file_icon.svg.png 1667w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/>\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t<div class=\"icon-box-text last-reset\">\n\t\t\t\t\t\t\t\t\t\n\n<h3>XJC_110_TDS_EN<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\t<\/a>\n\t\n\n<\/div><\/div><\/div>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1664060141 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n  background-color: rgb(237, 239, 242);\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section product-video-section\" id=\"section_1214152766\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1214152766 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section help-section\" id=\"section_140539611\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row align-middle help-row\"  id=\"row-1519118863\">\n\n\n\t<div id=\"col-1914193388\" class=\"col medium-8 small-6 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h5 class=\"jumbo-heading mb-0\">NEED ANY HELP?<\/h5>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-121491433\" class=\"col medium-4 small-6 large-4\"  >\n\t\t\t\t<div class=\"col-inner text-right\"  >\n\t\t\t\n\t\t\t\n\n\n\n<a href=https:\/\/wastetech.gr\/en\/contact\nclass=\"help-arrow\">\n<img decoding=\"async\" src=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg\">\n<\/a>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_140539611 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n  background-color: rgb(237, 239, 242);\n}\n<\/style>\n\t<\/section>\n\t\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":979,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"inline_featured_image":false,"footnotes":""},"class_list":["post-953","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Submersible drainage center-line pumps JC &amp; XJC | Wastetech<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Submersible drainage center-line pumps JC &amp; XJC | Wastetech\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/\" \/>\n<meta property=\"og:site_name\" content=\"Wastetech\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/wastetech.gr\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-09T19:39:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/\",\"url\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/\",\"name\":\"Submersible drainage center-line pumps JC &amp; XJC | Wastetech\",\"isPartOf\":{\"@id\":\"https:\/\/wastetech.gr\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg\",\"datePublished\":\"2024-10-30T13:15:23+00:00\",\"dateModified\":\"2025-06-09T19:39:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage\",\"url\":\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg\",\"contentUrl\":\"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae\",\"item\":\"https:\/\/wastetech.gr\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pumps\",\"item\":\"https:\/\/wastetech.gr\/en\/antlies\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Drainage center-line Pumps\",\"item\":\"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Submersible drainage center-line pumps JC &amp; XJC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/wastetech.gr\/en\/#website\",\"url\":\"https:\/\/wastetech.gr\/en\/\",\"name\":\"Wastetech\",\"description\":\"WASTETECH PC\",\"publisher\":{\"@id\":\"https:\/\/wastetech.gr\/en\/#organization\"},\"alternateName\":\"WASTETECH IKE\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/wastetech.gr\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/wastetech.gr\/en\/#organization\",\"name\":\"WASTETECH IKE\",\"alternateName\":\"\u039a\u03b1\u03c4\u03b1\u03c3\u03ba\u03b5\u03c5\u03ae \u03bc\u03b7\u03c7\u03b1\u03bd\u03b7\u03bc\u03ac\u03c4\u03c9\u03bd \u03b3\u03b9\u03b1 \u03b5\u03bc\u03c0\u03bf\u03c1\u03b9\u03ba\u03ad\u03c2 \u03ba\u03b1\u03b9 \u03c5\u03c0\u03b7\u03c1\u03b5\u03c3\u03b9\u03b1\u03ba\u03ad\u03c2 \u03b2\u03b9\u03bf\u03bc\u03b7\u03c7\u03b1\u03bd\u03af\u03b5\u03c2\",\"url\":\"https:\/\/wastetech.gr\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/wastetech.gr\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/07\/WT_LOGOTYPO-profile-pic.png\",\"contentUrl\":\"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/07\/WT_LOGOTYPO-profile-pic.png\",\"width\":7515,\"height\":4122,\"caption\":\"WASTETECH IKE\"},\"image\":{\"@id\":\"https:\/\/wastetech.gr\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/wastetech.gr\/\",\"https:\/\/www.linkedin.com\/company\/wastetech-p-c\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Submersible drainage center-line pumps JC &amp; XJC | Wastetech","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/","og_locale":"en_US","og_type":"article","og_title":"Submersible drainage center-line pumps JC &amp; XJC | Wastetech","og_url":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/","og_site_name":"Wastetech","article_publisher":"https:\/\/www.facebook.com\/wastetech.gr\/","article_modified_time":"2025-06-09T19:39:04+00:00","og_image":[{"url":"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/","url":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/","name":"Submersible drainage center-line pumps JC &amp; XJC | Wastetech","isPartOf":{"@id":"https:\/\/wastetech.gr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage"},"image":{"@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage"},"thumbnailUrl":"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg","datePublished":"2024-10-30T13:15:23+00:00","dateModified":"2025-06-09T19:39:04+00:00","breadcrumb":{"@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#primaryimage","url":"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg","contentUrl":"https:\/\/wastetech.gr\/wp-content\/uploads\/2024\/10\/Group-306.svg"},{"@type":"BreadcrumbList","@id":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/ypovrychia-antlia-apostrangisis-solinotou-typou-jc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae","item":"https:\/\/wastetech.gr\/en\/"},{"@type":"ListItem","position":2,"name":"Pumps","item":"https:\/\/wastetech.gr\/en\/antlies\/"},{"@type":"ListItem","position":3,"name":"Drainage center-line Pumps","item":"https:\/\/wastetech.gr\/en\/antlies\/antlies-apostrangisis-solinotou-typou\/"},{"@type":"ListItem","position":4,"name":"Submersible drainage center-line pumps JC &amp; XJC"}]},{"@type":"WebSite","@id":"https:\/\/wastetech.gr\/en\/#website","url":"https:\/\/wastetech.gr\/en\/","name":"Wastetech","description":"WASTETECH PC","publisher":{"@id":"https:\/\/wastetech.gr\/en\/#organization"},"alternateName":"WASTETECH IKE","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wastetech.gr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/wastetech.gr\/en\/#organization","name":"WASTETECH IKE","alternateName":"\u039a\u03b1\u03c4\u03b1\u03c3\u03ba\u03b5\u03c5\u03ae \u03bc\u03b7\u03c7\u03b1\u03bd\u03b7\u03bc\u03ac\u03c4\u03c9\u03bd \u03b3\u03b9\u03b1 \u03b5\u03bc\u03c0\u03bf\u03c1\u03b9\u03ba\u03ad\u03c2 \u03ba\u03b1\u03b9 \u03c5\u03c0\u03b7\u03c1\u03b5\u03c3\u03b9\u03b1\u03ba\u03ad\u03c2 \u03b2\u03b9\u03bf\u03bc\u03b7\u03c7\u03b1\u03bd\u03af\u03b5\u03c2","url":"https:\/\/wastetech.gr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/wastetech.gr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/07\/WT_LOGOTYPO-profile-pic.png","contentUrl":"https:\/\/wastetech.gr\/wp-content\/uploads\/2025\/07\/WT_LOGOTYPO-profile-pic.png","width":7515,"height":4122,"caption":"WASTETECH IKE"},"image":{"@id":"https:\/\/wastetech.gr\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/wastetech.gr\/","https:\/\/www.linkedin.com\/company\/wastetech-p-c\/"]}]}},"_links":{"self":[{"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/pages\/953","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/comments?post=953"}],"version-history":[{"count":0,"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/pages\/953\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/pages\/979"}],"wp:attachment":[{"href":"https:\/\/wastetech.gr\/en\/wp-json\/wp\/v2\/media?parent=953"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}